The PCRF-80P0 conducted immunity generator is a comprehensive test system for RF conducted and radiated immunity tests. It can meet the test requirements of IEC61000-4-6 (Electromagnetic Compatibility Part 4: Experiments and Measurement Techniques Part 6: Immunity Test for Conducted Interference Induced by Radio Frequency Fields) through different module configurations. It evaluates the working reliability and stability of electronic equipment in a conducted noise interference environment. It can help detect the immunity of equipment to external interference sources (such as power lines, communication cables, etc.) and provide data and results for engineering design and improvement.
Key Features:
Frequency Range: 150 kHz to 230 MHz
Test Voltage: Up to 30 Vrms
Test Modes: Standard and Custom
Interfaces: RJ45 and RS232 (Remote control)
Test Standard: EN/IEC 61000-4-6